FaithTech FT68206A-150-600 High Power Electronic Load 150V/600A/6kW
The FT68200A/AL/E series is a family of high power programmable DC electronic loads from FaithTech, designed for high reliability and high power density operation. It enables precision loading of DC sources under a wide range of dynamic, steady state, and transient test conditions. Single modules range from 6 kW up to 60 kW, and multiple units can be paralleled in master/slave configuration to scale to hundreds of kilowatts.
FT68206A-150-600 Unit range:
- Voltage: 0 to 150V
- Current: 0 to 600A
- Power: 0 to 6kW
- Dimensions: 4U, standard 19-inch chassis design
Key Features & Capabilities
Modules available in increments from 4kW to 60kW; parallel operation supports expansion up to 600kW or more.
Supports operating voltages of up to 1200V. Current capability per unit reaches up to 2400A in the lower voltage models.
Designed for compact size, the module density is roughly 6kW per 3U of rack height.
Precise Accuracy & Fast Response:
- Voltage measurement accuracy: ~0.025% + 0.025% FS.
- Current measurement accuracy: ~0.05% + 0.05% FS.
Dynamic programming (current control) up to 50kHz; sampling up to 500kHz.
30kHz dynamic sweep (frequency scan) capability to probe worst case voltage behaviour.
Multiplexed Operation Modes:
- Supports standard bias modes: CC (constant current), CV, CR (constant resistance), CP (constant power).
- Also supports combinations and advanced modes (e.g. CV + CC, CR + CC, CP + CC) and transient / dynamic modes (CRD, CPD) depending on variant.
Can handle instantaneous overloads of more than twice the rated power for short durations, aiding in stress testing.
Supports built in functions for OCP, OPP, battery discharge, internal resistance (ESR) simulation, LED load modelling, load effect simulation, auto test sequences, time measurement (0.1ms to 20h), and Vpeak+/Vpeak– measurement.
Standard interfaces: RS232, RS485, LAN, USB. Optional: GPIB, CAN. Protocol support: SCPI, Modbus RTU.
Comprehensive protections including over voltage, over current, over temperature, power limit, reverse polarity, memory of power-off state, etc.
Rugged design intended for continuous operation in demanding test environments.
Applications
Power battery, lead-acid battery, fuel cell discharge test
BMS and battery protection device testing
DC charging pile, charging module, vehicle charger, A/D power converter and other power electronic power device testing
Test high-power switching power supply, UPS power supply, communication power supply, server power supply
Virtual load testing of solar arrays and industrial motors
Additional Information
| Voltage | 150V |
|---|---|
| Current | 600A |
| Power | 6kW |
| Dimensions | 4U |
| FT68200A/E Function configuration list | ||
| Function | A | E |
| Constant current (CCH/CCL), Constant voltage (CVH/CVL) | ✓ | ✓ |
| Constant resistance (CR), Constant power (CP) | ✓ | ✓ |
| Dynamic current (CCDH/CCDL) | ✓ | ✓ |
| Dynamic resistance (CRD), Dynamic power (CPD) | ✓ | ✗ |
| Sequence (SEQ), Auto(AUTO) | ✓ | ✓ |
| Over current protection (OCP), Over power protection (OPP) | ✓ | ✓ |
| Discharge (DISCHARGE) | ✓ | ✓ |
| Load effect (LOEF) | ✓ | ✓ |
| Discharge resistance (ESR) | ✓ | ✓ |
| LED simulation (LED) | ✓ | ✗ |
| Dynamic scanning (SWEEP) | ✓ | ✓ |
| MPPT | ✓ | ✗ |
| CC+CV, CR+CV, CV+CC, CR+CC, CP+CC | ✓ | ✗ |
| Save and Recall | ✓ | ✓ |
| Remote compensation | ✓ | ✓ |
| Constant voltage velocity | ✓ | ✓ |
| Simulation programming | ✓ | ✓ |
| External control | ✓ | ✓ |
| Simulation short | ✓ | ✓ |
| Timed load | ✓ | ✓ |
| VON / VOFF | ✓ | ✓ |
| Limit set | ✓ | ✓ |
| Hardware limitation | ✓ | ✓ |
| Protection set | ✓ | ✓ |
| Time measurement | ✓ | ✓ |
| Vpk+/- | ✓ | ✓ |
| Data transmission | 1kHz/s | 1kHz/s |
| Front Parallel operation | ✓ | ✓ |